-70°C Dew Point
Desiccant Dehumidifier
DHU rotary desiccant dehumidifiers engineered for ultra-deep latent loads where typical cooling fails, maintaining dew points down to -70°C.
View SpecificationsPrecision moisture extraction units, VOC condensers, and ultra-dry room systems calibrated to strict psychrometric conditions.
-70°C Dew Point
DHU rotary desiccant dehumidifiers engineered for ultra-deep latent loads where typical cooling fails, maintaining dew points down to -70°C.
View Specifications
Turnkey EPC
Comprehensive envelope, precision air handling, filtration, and controls delivered under single-source EPC contracts for battery cells.
Explore Dry Rooms
Recovery ≥99%
Closed-loop condensation capturing N-Methyl-2-pyrrolidone vapors from coating lines, cutting solvent purchases and emissions.
NMP Recovery Systems
RTO + Cooling
Thermal oxidizers, zeolitic rotors, and cryogenic condensers designed for industrial emission compliance and solvent trapping.
VOC Abatement
Energy Efficient
Direct expansion sensible and latent moisture extractors for warehouses, pre-cooling stages, and general industrial moisture mitigation.
Refrigerative Units
Gigafactory Grade
Integrated rotor cascading assemblies configured for electrolyte filling and solid-state battery manufacturing requirements.
View Solutions
Heat Recovery
Multi-stage condensation technology engineered to reclaim process sensible heat while capturing 99%+ of exhausted chemical solvents.
Learn More
Clean Emission
High-flow hydrocarbon vapor control and oil gas collection skids designed to meet global EPA, TA-Luft, and GB industrial limits.
Explore VOC PlantsModern precision manufacturing processes no longer regard relative humidity (RH) as an ambient convenience. In lithium-ion gigafactories, biopharmaceutical suites, and aerospace storage, humidity is a chemical contaminant that triggers catastrophic cathode degradation, hydrolysis reactions, and surface corrosion.
With EV battery cell gigafactories scaling across Europe, North America, and Southeast Asia, moisture control directly determines electrochemical stability. Ambient moisture reacts with LiPF6 to form Hydrofluoric Acid (HF), triggering severe cell degradation and micro-short circuits.
Desiccant wheel reactivation represents up to 43% of total cleanroom HVAC utility consumption. Industrial exporters must engineer sophisticated heat exchangers, heat pumps, and low-temperature silica gel wheels to minimize operating expenditure (OPEX) in competitive global markets.
Biomedical API synthesizers, solid-state battery innovators, and semiconductor wafer fabs require supply air dew points ranging from -40°C to -70°C dew point. Mechanical chilling alone cannot achieve these moisture targets without freezing, making rotary sorption essential.
Four transformative technological pillars define the next era of industrial humidity mitigation and emissions handling systems worldwide.
Transitioning from standard synthetic silica to metal-organic frameworks (MOFs) and nano-porous zeolites. These materials reduce the required desorption reactivation heat threshold from 140°C down to 75°C, unlocking waste heat utilization.
Predictive neural networks continuously monitor ambient climate shifts, air-lock infiltration rates, and operator occupancy changes, dynamically throttling heating regeneration arrays to save 18–32% in seasonal power consumption.
Coupling heat-pump condensers directly with adsorption rotors creates a dual-zone closed-loop architecture. This prevents fugitive VOC leaks while ensuring ultra-low moisture delivery under extreme tropical wet-bulb conditions.
Stringent REACH and EPA environmental directives require solvent mitigation systems. Integrated deep-cooling condensation combined with RTO achieves over 99% NMP reuse efficiency, drastically lowering chemical disposal overhead.
DryAir customizes mechanical psychrometrics based on target process chemistries, strict international cleanroom envelopes, and regional climate variations.
Supply air controlled to -40°C to -70°C dew point across cell winding, jelly-roll stacking, and electrolyte injection cleanrooms. Eliminates Hydrofluoric acid formation, protecting workers and ensuring superior battery life cycles.
Maintaining 10%–25% RH inside fluid bed dryers, gelatin capsule filling bays, and lyophilization packaging corridors. Complies with cGMP, preventing powder agglomeration, formulation degradation, and microbial growth.
Built under the national military GJB standards. Deploys hermetic preservation to halt corrosion, optics fogging, and pyrotechnic decay for naval vessels, avionics bays, and strategic ordinance vaults.
Prevents oxidation of lead frames, photoresist peeling, and electrostatic discharge (ESD) variations. Delivers ultra-pure airstreams devoid of chemical airborne molecular contamination (AMC).
Deep-cooling condensation paired with regenerative thermal oxidizers (RTO). Captures hydrocarbon gas flaring, tank breathing vapors, and organic exhaust throughout bulk chemical transshipment terminals.
Stops hygroscopic clumping in infant formulas, functional whey proteins, and instant coffee towers. Ensures year-round stable packaging rates unaffected by monsoon seasonal humidity spikes.
Founded in 2010, Hangzhou DryAir Treatment Co., Ltd. has established market leadership across China's industrial desiccant dehumidification landscape.
Staffed by 74 specialists including registered HVAC engineers, PhD researchers, and master’s scholars. Our team models internal air velocities, thermal barriers, and air-lock leakage before production begins.
Supplying critical equipment for leading cell manufacturers like CATL, BYD, ATL, EVE, Envision, and SVOLT, as well as global manufacturers like Tesla, Northvolt, and TTI across Europe and North America.
With a steady production capacity exceeding 200 units per month, our facilities scale to support parallel gigafactory construction without extending procurement lead times.
Specifying an incorrect humidity baseline can result in high scrap rates or wasted energy. Use these verified parameters for procurement planning.
| Application & Industrial Process | Typical Controlled Target | Recommended Machine Series | Verified Operational Outcome |
|---|---|---|---|
| Li-ion Cell Assembly & Electrolyte Injection | -40°C to -60°C DP | Turn-key Dry Room System | Stops HF acid corrosion and prevents cell swelling |
| Solid-State & Lithium Metal Battery Labs | Down to -70°C DP | Desiccant Dehumidifier | Prevents moisture reaction with pure lithium metal |
| Electrode Slurry Coating & Oven Exhaust | ≥99% Solvent Recovery | NMP Recovery System | Cuts raw chemical purchasing costs and stack emissions |
| Hygroscopic Pharma Granulation & Capsuling | 10% to 30% RH | Desiccant Dehumidifier | Eliminates powder caking and complies with cGMP |
| Ammunition, Ordnance & Military Storage | ≤40% RH | Desiccant Dehumidifier | Stops oxidation under national military GJB specs |
| Raw Material Warehouses & Pre-cooling Arrays | 45% to 60% RH | Refrigerative Dehumidifier | Cost-effective bulk moisture removal prior to sorption |
| Bulk Fuel Terminals & Solvent Vapour Loading | Emission Limits / Clean Air | VOC Abatement System | Deep condensation to satisfy global environmental standards |
From initial thermodynamic calculations to on-site commissioning, our engineering team manages the complete lifecycle.
Analysis of door-opening frequencies, personnel infiltration, fresh air loads, and building envelope leakage factors.
CFD airflow analysis, rotor cascade sizing, energy recovery integration, and full control system design.
In-house manufacturing of structural panels, desiccant rotors, and electrical panels, followed by rigorous testing.
Global mechanical assembly, cleanroom balancing, and validation of steady-state dew point performance.
Field-tested engineering strategies addressing common operational bottlenecks in demanding processing environments.
Oil gas condensation recovery systems capture fuel and chemical vapors during tank filling and transfer. Discover how multi-stage chilling condenses volatile organic vapors before exhaust discharge.
Read Technical Paper
NMP is an essential solvent in cathode slurry coating. This study covers closed-circuit cooling profiles, VOC sensors, and condensation curves required to maintain >99% recovery in 24/7 operations.
Read Technical Paper
From active powder processing to tablet pressing and blister packaging, unmonitored humidity degrades product efficacy. Learn how rotary desiccant systems help plants meet cGMP standards.
Read Technical PaperEssential information on export compliance, system sizing, energy recovery, and international on-site maintenance.
Compare specifications and explore systems engineered to solve moisture, recovery, and emission challenges worldwide.
DP -70°C Spec
DHU industrial rotary dehumidifiers maintain stable, deep dew point supply air, supporting critical operations where mechanical cooling cannot suffice.
Product Details
Turnkey EPC
Fully integrated, ultra-low dew point cleanroom spaces engineered for lithium-ion battery production, from design through validation.
Explore Dry Rooms
99%+ Capture
Condensation-based recycling plants designed for battery electrode lines, helping lower production costs and meet environmental standards.
NMP Solutions
Compliant RTO
Regenerative Thermal Oxidizers (RTO) and cryogenic cooling systems that destroy hazardous VOC emissions and keep plants compliant.
VOC Systems
High Reliability
Direct mechanical cooling dehumidification for pre-treatment air handling, pharmaceutical warehouses, and general moisture protection.
Refrigerative Units
Vapor Control
Deep-freeze condensation modules designed for volatile hydrocarbon loading racks, bulk fuel farms, and offshore terminals.
Vapor Recovery
Thermal Reuse
Closed-loop energy and solvent recycling tailored for modern high-speed continuous roll-to-roll electrode coating lines.
View System
cGMP Sanitary
Hygienic, fully washable rotor systems engineered to control low relative humidity in powder, capsule, and sterile production suites.
Pharma SystemsProvide your process requirements, target dew point, or room layout. Our HVAC engineers will calculate your moisture loads and provide a tailored system proposal within one business day.